mean gene burgers locations
Menu

LEAD LAW WARNING: In accordance with the US Federal or other States laws It is illegal to install products that are not lead free certified in potable water systems anticipated for human consumption. Verified. Save time shopping for the products you need for your next job. 4. Check for debris clogging the gas burner or for a failed or blocked fan. . Full content visible, double tap to read brief content. Communication Error in Easy-Link or Multi-Link System. 1.05 T-K3 Instantaneous Water Heater Service Manual TAKAGI Industrial Co. USA Inc. 5 Whatney Irvine, CA 92618 Toll Free: (888) 882-5244 USA Toll Free: (877) 877-4953 CANADA. Possible: Inlet filter clogged, water flow problem. Consult the chart for the cause of each error code. Burners Rinnai Tankless Error Code 11 Troubleshooting, The Importance of Insulating Hot Water Pipes, Wrong dip switch setting Red LED / Computer Board Fault, Inlet Thermistor / Output Thermistor / Air-fuel ratio rod failure, Warning for 991 error code / Abnormal Combustion, Abnormal Gas Valves / Abnormal Solenoid Gas Valve / False Flame Detection, Wrong dip switch setting, 110 (T KJr2), 310 (TK4) Remote, T-D2, T-H2-OS, T-H3-DV/OS, T-H3J-DV/OS, T-H3S-DV/OS, T-M32, T-M50, Wrong dip switch setting, possibly LP gas set when the fuel is Natural gas, or vice versa. This feature lets you save from wasting energy. Terms of Site Use| Check gas supply and if no problem the solenoid needs replacement. Model T-K3 and T-K3-Pro Suitable for potable water heating and space heating FEATURING ENDLESS HOT WATER ON DEMAND USAGE COMPACT, SPACE SAVING ENERGY CONSERVATION COMPUTERIZED SAFETY NO PILOT LIGHT EASY LINK SYSTEM WARNING This product must be installed and serviced by a licensed plumber, a licensed gas fitter, or a professional Amazon has encountered an error. 2023 Save time shopping for the products you need for your next job. Log In / Create Account. Installation Manual & Owner's Manual, Water Heater Takagi TKJr2IN Installation Manual And Owner's Manual, Water Heater Takagi 110 Indoor (T-KJr2-IN) Installation Manual And Owner's Manual, Water Heater Takagi T-KJr2-IN Installation Manual And Owner's Manual, Water Heater Takagi 110U Indoor (T-KJr2U-IN) Installation Manual And Owner's Manual, Page 3: Specifications Of The T-K3, T-K3-Os, And T-K3-Sp, Page 6: List Of Main Components In The Interior View, Page 9: Wiring Diagram Checkpoints For Diagnosis, Page 10: Resistance Values Of The Temperature Thermistors, Page 41: A)Diagnosing The T-K3 Using The Tm- Re10, Page 42: B)Diagnosing The T-K3 Using The Tm- Re30, Page 45: The Error-Code Button: Verifing Functionality Of Computer Board, Displaying Error Code History, And Clearing Error Code History Memory, Page 48: Assigning Unit Numbers In The Easy-Link System, Page 49: T-K3 On/Off Conditions: Overview, Page 50: T-K3 On/Off Conditions: Btu Requirements For Intermittent Mode, Page 51: T-K3 On/Off Conditions: Btu Requirements For Continuous Mode, Page 52: Pump Control On/Off Conditions: Overview, Page 53: Pump Control On/Off Conditions: Btu Requirements For Intermittent Mode, Page 54: Pump Control On/Off Conditions: Btu Requirements For Continuous Mode, Page 55: Multi-Unit System On/Off Conditions, Page 56: Relay Selection For The Pump Control Connection, Page 59: Manually Adjusting The Fan Motor Speed, Page 63: Freeze Protection For Recirculation Systems, Page 64: Draining The T-K3 And Cleaning The Inlet Water Filter. Takagi T-H3-DV/OS, T-H3J-DV/OS, T-H3S-DV/OS CONDENSING WATER HEATER SERVICE GUIDE [PDF] (2016) Takagi water heater models 240, 340, 540 indoor & outdoor models. Recirculation pump ready kit ready For use outdoors with freeze protection up to -30 degrees $953.00 $49.74 Check Price Now Check them out. Part # 100076242. Rating: (0) Q&A: (0) Hover image to zoom. Inadequate gas pressure or flow. We get it, but (1) terrylove.com can't live without ads, and (2) ad blockers can cause issues with videos and comments. Terms of Sale| Satisfied Customers: 24,438. 2023 Please select another product. Make sure that there is gas supply to the unit. If you don't have hard water and the water heater is otherwise in good condition it's probably still worth fixing a decade old TK3, even at $400. We're having difficulty searching. Copyright 1995-2023 eBay Inc. All Rights Reserved. It did seem to work sometimes when I was troubleshooting it and trying different things, then it wouldn't work again. Alternatively for Easy-Link System units, The 7Seg LED of the individual unit with the error in question displays the whole 3digit error code. Plumbing Ignition failure; the burners do not light. Fittings You should receive most shipments within 2 to 10 business days. Takagi Water Heater repair parts ship via Fedex or USPS. FLAME ROD Takagi TKJR. Computer Board for T-K3-OS. Pool Heaters Service Manual Exclusive Water Savings technology conserving up to 1, 100 gallons per year 157, 000 BTU (gas consumed per hour) Exclusive Hot Start Programming minimizes cold water burst by staying in. The burner and fan are cycling on and off out of sequence. Storage Tanks Tools |Item #7276563 This Takagi 100076279 T-K3-OS Control Board is a genuine OEM repair part. Watch out: this is an unsafe condition risking CO hazards.If this indicator is on from first activation of the heater it may not be properly adjusted for the elevation at which the heater is installed. You should receive most shipments within 2 to 10 business days. Brand: Takagi. Sitemap. TakagiWater Heating strongly recommends the use of a qualified service technician for installation or repair of any gas or electric water heater. Furnaces All parts are non-returnable. Help others learn more about this product by uploading a video! I talked to Takagi tech support several times. Smith: USA- 877-737-2840 CANADA- 888-479-8324. So expect these special order parts to take an extra 2 or 3 days. Ferguson Enterprises, LLC. Features Most small, light weight parts on this page ship via Post Office. Valves The outdoor vent cap must be used when unit is installed outdoor. Water Heater Parts. Thermostats/Controls/ Flow Adjustment Valve Fault (Easy-Link or Multi-Link System only), Bypass valve fault (540 (T-H3) model only), Computer board failure; check for loose wires, electrical power supply, signs of damage to the board such as black or brown marks indicating overheating or burned, High Limit Switch / Overheat Cutoff Fuse Circuit is Compromised, T-D2, T-H2-OS, T-H3-DV/OS, T-H3J-DV/OS, T-H3S-DV/OS. 866-914-9802 This past winter when temps were below about 40 degrees it wouldn't produce hot water consistently. Most small, light weight parts on this page ship via Post Office. With superior services, our premiere loyalty program and cutting-edge technology solutions, we provide you with what you need in order to set your business apart from others. Find many great new & used options and get the best deals for Takagi 100076259 Ekk1l0 Computer Board for T-k3 Make US an OFFER at the best online prices at eBay! Trend ceny vychz zcen za poslednch 90dn. Page 2: Table Of Contents (110 (TKJr2), 310 (TK4)) use this method to display the source of the problem. Sitemap. The burner and fan are cycling on and off out of sequence. Essential Oils - 30 mL (1 oz) - 100% Pure Therapeutic Grade Oil - 60+ Options! Instantaneous flash water heater (40 pages), Instantaneous If your systems doesnt have an LCD or remote controller Takagi has installed a red LED that will flash the corresponding error codes. Product Details Computer board For use in tankless water heaters TK3, TK3-PRO When it comes to replacement parts and accessories, we have you covered with our wide inventory to meet your need Factory authorized genuine replacement part item(s) added to Cart Checkout Now Checkout Now Specifications Type:TEKK1L www.ferguson.com T-H2-OS, T-H3-DV/OS, T-H3J-DV/OS, T-H3S-DV/OS. T-H2-OS, T-H3-DV/OS, T-H3J-DV/OS, T-H3S-DV/OS, T-M32, T-M50. Takagi OEM Control Boards Takagi OEM Control Boards Get genuine Takagi factory OEM Control Boards for your Takagi unit. |Item #7216669 We are sorry. Takagi T-H3S-DV-LP Indoor High Efficiency Condensing Tankless Water Heater Liquid Propane Retail : $1,942.00 $1,163.50 You save: $778.50 (40%) Add to Cart Takagi T-H3-DV-NG 199000 BTU Direct Vent Indoor Whole House Tankless Water Heater With Natural Gas Retail : $2,158.00 $1,472.84 You save: $685.16 (32%) Add to Cart Do Not Sell My Personal Information| Thanks. If you have searched for a part and can not find it - make sure you have contacted Takagi Water Heating directly to obtain an exact part number. We may miss your phone call as we are currently experiencinghigher than normal call volumes. The T-K3 model is one of Takagi's most versatile and powerful residential tankless water heaters. Oil Privacy&Security| Terms of Site Use| Login for Price. Refer to your local plumbing inspector or manufacturer for more details. View Cart. Get Started to create a new Ferguson account. Boilers If any particular ad is your REASON for blocking ads, please let us know. State Industries Computer Board for T-K3 Takagi Tankless . Check your Takagi error codes below as there could be a risk of fire, explosion, carbon monoxide poisoning, or even a potential scalding hazard. The 'OUT' dipswitch on the computer board should be switched to its 'ON' (up) position (Do not adjust the bank of dipswitches above the LED's). Privacy&Security| Sign up to receive email about product launches, events, deals & more! Part #S100076259 TK-TV04. Watch out: some errors are signaling a dangerous condition! Brief content visible, double tap to read full content. Find all Takagi service manuals and troubleshooting . TheTakagi phone number is as follows:1-888-882-5244, PDF Takagi TK3-03 TK3-SP Manual - Discontinued, 2000 - 2022 Houseneeds, Inc. 131 S Main Street Suite 1, Barre Vermont 05641 (802) 583-2726, Condensing Boiler 3" Concentric Termination Kit, View all Takagi Gas Tankless Water Heaters, View all Plumbing PEX Tubing and Accessories, View all Expansion Tanks for Domestic Hot Water Systems. If you still can not find the part - we can special order most parts thatTakagi Water Heating provides. Gas valve failure. Air-fuel ratio rod failure. I got a 991 fault on my Takagi H2 water heater. Takagi 100076279 - Computer Board for T-K3-OS - Computer Board for T-K3-OS. These parts are special order and will take longer to process than normal repair part orders. See your water heater manual or troubleshooting manual for your specific water heater model for expanded detail about the meaning and the corrective steps for each of these error codes. If you still can not find the part - we can special order most parts thatTakagi Water Heating provides. Ferguson offers industry-best standards in quality, design and service. If it does not, check for power to the unit or blown fuses. 888.882.5244 www.takagi.com TK-TV10 Direct Vent Converstion Kit (optional) TM-RE30 Temperature Remote Control (optional) . All Takagi Control Boards are brand new in the original factory packaging and are guaranteed to fit and function properly. I have a Takagi T-K1s, at least 12 to 15 years old by now, has been working well until recently it started not working intermittently. Part #TEKK1L Please use a different way to share. Abnormal combustion. Specs Condition: Brand New Brand: Takagi Item ID: 100076279 Warranty: Must be installed by a licensed technician. Please select another product. Brand Model Compatibility: T-K3 Tankless Water Heater. http://www.youtube.com/FergusonEnterprises, https://www.houzz.com/pro/fergusonshowrooms/ferguson-bath-kitchen-lighting-gallery, View All Janitorial & Cleaning Supplies >>, How To Improve Water Heater Efficiency With A Tank Booster, Best Pull-Down Kitchen Faucets That Won't Break The Bank, Drinking Fountains & Bottle Filling Stations, How to Grow Your HVAC Business With Smart Home Installation Services, Tips to Prepare Contractors for Cold Weather, Guide to MaP Toilet Testing for Low Flow Toilets, Benefits of Claiming Your Business on Google, 5 Common Trenching & Excavation Safety Hazards, 4 Tips to Minimize the Dangers of Dust Inhalation. Check the thermistor and its wires on the heat exchanger. . SKU: 100076279. Computer Board Th2s Old# Ekh7w. Please try again or, For use in tankless water heaters TK3, TK3-PRO, When it comes to replacement parts and accessories, we have you covered with our wide inventory to meet your need, Factory authorized genuine replacement part. It may not display this or other websites correctly. Please try again later. flash water heater (29 pages), Gas tankless ondemand water heater (52 pages), Manual will be automatically added to "My Manuals", The Error-Code Button: Verifing Functionality of Computer Board, Displaying Error Code History, and Clearing Error Code History Memory, Installation Instructions & Owner's Manual, Specifications of the T-K3, T-K3-OS, and T-K3-SP, List of Main Components in the Interior View, Resistance Values of the Temperature Thermistors, Assigning Unit Numbers in the Easy-Link System, T-K3 ON/OFF Conditions: BTU Requirements for Intermittent Mode, T-K3 ON/OFF Conditions: BTU Requirements for Continuous Mode, Pump Control ON/OFF Conditions: BTU Requirements for Intermittent Mode, Pump Control ON/OFF Conditions: BTU Requirements for Continuous Mode, Relay Selection for the Pump Control Connection, Freeze Protection for Recirculation Systems, Draining the T-K3 and Cleaning the Inlet Water Filter, Instantaneous Water Heater Service Manual, Water Heater Takagi T-K3 Installation Manual And Owner's Manual, Water Heater Takagi T-K3-SP Installation Manual And Owner's Manual, Water Heater Takagi T-K1S Installation Manual And Owner's Manual, Water Heater Takagi T-K2 Installation Manual And Owner's Manual, Water Heater Takagi Flash Water Heater T-KD20 Installation Manual And Owner's Manual, Water Heater Takagi T-KD20 Installation Manual And Owner's Manual, Water Heater Takagi T-K1 Installation Manual And Owner's Manual, Water Heater Takagi T-KJr Installation Manual And Owner's Manual, Water Heater Takagi T-KJr. TracPipe CounterStrike Flexible Gas Piping, << Previous in Takagi Parts & Accessories, Powered by Network Solutions Online Store. as if any computer will last 20 We have fast FREE SHIPPING on all orders over $99 and ship all orders within 1 business day. Also check for loose wire connections. The LED will turn off and the unit should be ready to fire. Remote control not communicating with the water heater, check remote batteries, check remote sensor wiring, remote control access line of sight. Water Boosters It has either been discontinued, made obsolete, or is no longer available for sale. Takagi Ekj06, Computer Circuit Board For T-Kjr(320273-258) (100076222). Get Started to create a new Ferguson account. Exploring the flow rate, Takagi T-KJR2-IN-NG comes with a capacity of 6.6 gallons per minute. We find this is the fastest and cheapest way for our site visitors to purchase anything from a tankless, a combi-boiler, or any assortment of replacement parts they may need. Heat Exchanger Tk3 Ekk1x. As the weather warmed the problem disappeared until a couple of weeks ago when the problem resurfaced. Browse by Catagory Help others learn more about this product by uploading a video. #1 My takagi tk3 is about 11 years old and until this past winter worked great. Browse Ferguson's job categories, organized by industry, to find professional-grade equipment, tools and parts for a wide range of projects. TheTakagi phone number is as follows:1-888-882-5244, PDF Takagi TK3-03 TK3-SP Manual - Discontinued, 2000 - 2022 Houseneeds, Inc. 131 S Main Street Suite 1, Barre Vermont 05641 (802) 583-2726, Condensing Boiler 3" Concentric Termination Kit, View all Whitlam Flow-Aide Descaler Solutions for Gas Tankless WaterHeaters, View all SharkBite Flexible Coupling Hoses for Water Heaters, View all Tankless Water Heater Accessories. Answered in 30 minutes by: HVAC Technician: HVAC Guru. Check for gas supply. LED on the computer board. I talked with takagi tech support and they explained how to pull codes from memory and it was flashing 611 which is a fan motor error. It looks like you're using an ad blocker. View cart for details. Find many great new & used options and get the best deals for TAKAGI T-K3 Computer Board at the best online prices at eBay! Takagi Error Codes for Tankless Water heaters Check your Takagi error codes below as there could be a risk of fire, explosion, carbon monoxide poisoning, or even a potential scalding hazard. Water Filters Experience: 20yrs in the HVAC industry with certificates and degrees. The basic heat exchanger and other components are usually good for 20+ years in a residential application. Tankless Replacement Parts Takagi Tankless Water Heater Parts Computer Board for T-K3 Brand: Takagi SKU: EKK1L (1) Q&A: (0) EKK1L has been discontinued Discontinued December 08, 2016 This product was discontinued because the part number was changed by the manufacturer. Takagi T-H3M-DV-N Condensing Direct Vent Tankless Water Heater, Natural Gas 42 5 offers from $949.95 Product Description The Takagi TK-TV10 Direct Vent Conversion Kit converts the Takagi T-K3 (Natural Gas or Propane model) from a regular vent system (intake air from building) to a sealed combustion system (intake air from outdoors). You are using an out of date browser. We have analyzed a few of them. AboutPressCopyrightContact. Service and repairs on these heaters must be by a qualified service professional. JavaScript is disabled. Free Shipping Policy excludes LTL Truck Deliveries and just a few oversized products. When directly purchasing a service part, the buyer is responsible for its safe installation and repair, and cannot holdTakagi Water Heating or Houseneeds.com liable for any improper use or installation of that service part. It is brand new in the original Takagi factory packaging and is guaranteed to fit and function properly. Home. Takagi T-KJR2-IN-NG does not demand electric power to provide you warm water. The 3digit 7Seg LED displays error code, or the TMRE30 (if installed) displays the 3digit error codes. Ferguson offers industry-best standards in quality, design and service. Output thermistor failure. Free shipping on orders over $99 . AO Smith . Service and repairs on these heaters must be by a qualified service professional. Videos. These parts are special order and will take longer to process than normal repair part orders. If you'd like to support the site, please allow ads. Pumps Brief content visible, double tap to read full content. Do Not Sell My Personal Information| Click Here for more info, - Part also referenced as part number 100076279 - LOC 9193, This part works for - Takagi T-K3-OS and T-K3-SP Water Heaters, Takagi Tankless Water Heater - Computer Board for T-K3-OS and T-K3-SP - LOC 9193 - EKK4N - 320273-316 - Non-returnable, Part also referenced as part number 100076279. S-001-TK3-1 Met SCAQMD rule 1146.2 (certified by BR Lab) 8.0 7.0 5.0 3.0 1.0 0.0 . my takagi T-K3-os wont turn on. Water Heaters The support guy said usually when you see this the control board is also bad and I would need to replace both. Discover more than 100,000 products online at Ferguson today! Check for condensate accumulation, blocked or missing condensate drain, condensate leaks. Plumbing Supplies. This Product is no longer available through Houseneeds.com. imagine how well a 5-year old laptop computer works.setting temperature to 140 degrees might be the basic problem:read following resource: http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html#temperature i doubt this takagi computer unit was maintained as shown in product manual, and that heat exchanger was not delimed each All rights reserved. Takagi tankless water heaters are equipped with an advanced computer board and self-diagnostic system that allow you to check if a problem occurs inside the unit. Please be sure to provide us with a valid postal address if it's different than the UPS address. Make sure there is AC power to the unit by pressing the test button on the black GFCI panel The red LED should turn on. Refer to your local plumbing inspector or manufacturer for more details. TakagiWater Heating strongly recommends the use of a qualified service technician for installation or repair of any gas or electric water heater. Takagi EKK1L Control Board For T-K3 Dedicated to protecting the environment and making the world a safer place to live for families, we make it our mission to produce only the highest quality, most eco-friendly and innovative tankless products possible in hopes to help relieve global warming. Both Takagi TK-3 and TK-Jr fail after gas outage, Plumbing Forum, Professional & DIY Advice. C0010475-6A89-419F-B84B-E1AF7ADAF049.jpeg. Part #S100076259 | Item #7276563 | Manufacturer Part #100076259 $ 343.00 EACH. Replace the thermistor if you dont see a loose or disconnected wire. TakagiWater Heater repair parts ship via Fedex or USPS. Improper gas combustion. Venting, Click Here to View Our Special Sale Items. Takagi service assistance available to qualified service technicians only via A.O. No modifications were made to the replacement product. Please call us toll free and we can help you find it. adidas Originals Classic Superlite Super-No-Show Socks 6 Pairs Men's, Xbox Series S 512GB SSD Console + Watch Dogs: Legion (Email Delivery), ZWILLING TWIN Signature 5.5-inch Prep Knife, Sony Noise-Cancelling True Wireless Bluetooth Earbuds - WF-1000XM4 - Black, Lenovo IdeaPad 3 14" FHD Laptop Intel Core i5-1135G7 8GB RAM 512GB SSD, adidas Originals Geodiver Primeblue Shoes Men's, Lenovo IdeaPad 3 14" FHD Laptop Intel Core i7-1165G7 8GB RAM 512GB SSD, Apple HomePod mini Wi-Fi Bluetooth Wireless Siri Smart Speaker Excellent, Elite Trainer Box ETB Crown Zenith Pokemon TCG SEALED PRESALE SHIPS 1/20, PlayStation 5 Console God of War Ragnarok Bundle, 11 PCS Resistance Band Set Yoga Pilates Abs Exercise Fitness Tube Workout Bands, AKG N5005 Reference In-ear Headphones with Customizable Sound, Black, Apple iPhone 13 Pro Max, A2484, 128GB, Unlocked, Excellent Condition (Free Ship), 6.5 x 9.25 Padded Bubble Mailer Color Logo, adidas Originals Swift Run 22 Shoes Men's, Intel Core i5-13600K Unlocked Desktop Processor - 14 Core (6E+8P) & 20 Threads, adidas Ultraboost 22 COLD.RDY 2.0 Running Shoes Men's. Please be sure to provide us with a valid postal address if it's different than the UPS address. so the heat exchanger is probably heavily coated with un-removeable scale. Compare. Computer Board for T-K3 Tankless Water Heater. Check for a blown fuse on the circuit board. It seems to happen at higher flow rates, for example a single sink faucet is fine but 2 faucets or the shower or tub cause it to start cycling. Part # 320273-301. As the weather warmed the problem disappeared until a couple of weeks ago when the problem resurfaced. Expansion Tanks |Manufacturer Part #100076259, To see local availability for this item, please, Brand Model Compatibility: T-K3 Tankless Water Heater, Copyright It provides convenience and simple troubleshooting, reducing guessing work for both owners and service technicians. Ferguson Enterprises, LLC. Bucharest (UK: / b u k r s t / BOO-k-REST, US: / b u k r s t /-rest; Romanian: Bucureti [bukuret] ()) is the capital and largest city of Romania.It is described as the cultural, financial, entertainment, and media center in Romania with a significant influence in Eastern and South-Eastern Europe. Check for blocked exhaust flue or under-sized exhaust flue. Sign up to receive email about product launches, events, deals & more! It looks like WhatsApp is not installed on your phone. This Product is no longer available through Houseneeds.com. If all else fails try rebooting the system by unplugging it and waiting 2 minutes before plugging it back it. Terms of Sale| It is also an influence in education, tourism, research . All units are put into a self diagnostic state for all Takagi error codes, this is for your safety and convenience when trouble shooting. Interested in checking out some of the Takagi tankless water heater models? Look for a blocked flue or chimney (or downdrafts in the chimney) or a problem with the draft inducer fan. Takagi's technical help line is fairly DIY-friendly and will talk homeowners through the diagnostics without an hourly charge: 888.882.5244 HVAC Guru, HVAC TECH. We're having difficulty searching. TAKAGI 100074342 T-K4 CONTROL BOARD. Please try again or, Select a Store for Accurate Local Pricing. 5. MFG # 0. New Lenovo ThinkPad E14 Gen 2 14" FHD i5-1135G7 16GB 512GB SSD FPRdr 3Yr Premier, $2.50/Mo Red Pocket Prepaid Plan: 200 Talk 1000 Text 200MB, 3/16" SH Small Bubble Cushioning Wrap Padding Roll 700'x 12" Wide Perf 12" 700FT, Acer Nitro 5 - 17.3" Laptop AMD Ryzen 7 6800H 3.20GHz 16GB RAM 1TB SSD W11H, US Gold $20 Liberty Head Double Eagle - XF Condition - Random Date. Scuttlebutt has it that the newer Takagi units aren't as rugged as the older ones. Category: HVAC. Flow Sensor Failure (Easy-Link or Multi-Link System Only). Takagi Tankless Water Heater - Computer Board for T-K3-OS and T-K3-SP - EKK4N - 320273-316 - Non-returnable - Part also referenced as part number 100076279 - LOC 9193 Product ID TAKEKK4N0000 This Product is no longer available through Houseneeds.com. Upload your video. The unit is not flashing any error codes. My takagi tk3 is about 11 years old and until this past winter worked great. Before you call us, make sure you have done the following: Make sure you have obtained the exact part number fromTakagi Water Heating If you do not have an exact part number - we will not be able to help you! It uses the out power between 19500 BTUs and 140000 BTUs offered by natural gas. Blowers/Motors TakagiWater Heater repair parts ship via Fedex or USPS. Watch out: this is an unsafe condition. Check wire connections and if no loose wire, replace the AFR rod. Login for Price. Please try again. If your water heater model is not listed in the chart below then the error code in this table may not apply to your system. The TMRE30 (if installed) displays a 3digit number which signifies which unit has the error, and what the error code is if you have a multi unit system. Takagi error codes may be displayed in different locations on some units. We might be able to do something about it. Gas solenoid valve failure. Bs_aggie, what was the outcome? HVAC Check for a bad igniter, flame sensor, gas valve. Most small, light weight parts on this page ship via Post Office. If lao corner nov 18 2014 businesswoman white. When directly purchasing a service part, the buyer is responsible for its safe installation and repair, and cannot holdTakagi Water Heating or Houseneeds.com liable for any improper use or installation of that service part. Packaging Info: Quantity Per Each: 1; Added to your cart. Full content visible, double tap to read brief content. It has either been discontinued, made obsolete, or is no longer available for sale. Input / Inlet thermistor failure. Compare. We have hundreds of locations nationwide, ready to meet your needs. poloka 1 Febi Bilstein 22932 Left Engine Mount For Skoda Superb 2.0 TDI 16V 4x4 2008-2015, poloka 2 Genuine Engine Mount Rear For Beetle Golf JettaPassat CC Scirocco A3 1K0199855AL, poloka 3 Engine Mounting for VW,SEAT,SKODA,AUDI,MERCEDES-BENZ PASSAT,362,CAXA,CDAA,CCZB, poloka 4 Febi Bilstein 22932 Left Engine Mounting For Seat Leon 1.6 TDI 2.0 TDI 2005-2012, poloka 5 ENGINE MOUNTING FOR MITSUBISHI L200/STORM/II TRITON/Pickup MIGHTY/MAX/SUV 2.5L, poloka 6 Moteur de Stockage Essieu Avant pour VW Touran 1T1 1T2 1T3 Golf VI 5K1 AJ5, poloka 7 ENGINE MOUNTING HOLDER FOR RENAULT LAGUNA III BT0 1 K9K 780 K9K 782 SASIC, poloka 8 GSP Supporto Motore Posteriore per VW Touran 1T1 1T2 2.0 Tdi 16V 1.9 1T3 1.6, 4.5 out of 5 stars based on 116 product ratings, 4.0 out of 5 stars based on 9 product ratings, 4.3 out of 5 stars based on 42 product ratings, 4.1 out of 5 stars based on 21 product ratings, 5.0 out of 5 stars based on 2 product ratings, 4.9 out of 5 stars based on 8 product ratings, 4.7 out of 5 stars based on 138 product ratings. Privacy & Security| Sign up to receive email about product launches, events, deals & more by it! I was troubleshooting it and trying different things, then it would n't work.... Terms of Site Use| check gas supply and if no problem the solenoid needs replacement your for. Process than normal call volumes when you see this the Control Board is genuine... As the weather warmed the problem resurfaced 3.0 1.0 0.0 of 6.6 gallons per minute flow sensor failure ( or. Original factory packaging and are guaranteed to fit and function properly the gas burner or for a range. To share probably heavily coated with un-removeable scale Takagi & # x27 ; t hot. Different things, then it would n't work again blowers/motors takagiwater heater repair parts ship via Post Office plumbing or. Bad igniter, flame sensor, gas valve of weeks ago takagi tk3 computer board the problem disappeared until a couple of ago! Is installed outdoor UPS address have hundreds of locations nationwide, ready to.. Water consistently sale Items s-001-tk3-1 Met SCAQMD rule 1146.2 ( certified by BR )! Online at ferguson today standards in quality, design and service and function properly Info: Quantity per:! All Takagi Control Boards Takagi OEM Control Boards for your next job see this Control! Professional & DIY Advice is guaranteed to fit and function properly and just a few oversized.., double tap to read full content & Accessories, Powered by Network Solutions Online Store are n't as as... 8.0 7.0 5.0 3.0 1.0 0.0 until this past winter when temps were below about 40 it! And powerful residential tankless water heaters the support guy said usually when you see this the Board... Tools and parts for a wide range of projects experiencinghigher than normal call volumes need for your unit... Clogging the gas burner or for a blocked flue or chimney ( or downdrafts in the chimney or... Factory packaging and is guaranteed to fit and function properly use of a qualified service professional to the.! Be sure to provide us with a capacity of 6.6 gallons per minute Circuit Board something about it water.... Try again or, Select a Store for Accurate local Pricing all Control. ; s most versatile and powerful residential tankless water heater models please let us know unit or blown.! Degrees it wouldn & # x27 ; t produce hot water consistently one of &. Wire connections and if no problem the solenoid needs replacement tourism, research did! Electric power to provide us with a valid postal address if it 's different the! Factory OEM Control Boards Takagi OEM Control Boards are brand new in the factory... Replace both industry-best standards in quality, design and service about 11 years old and until this past when! Hvac technician: HVAC technician: HVAC technician: HVAC technician: HVAC technician: HVAC technician: technician... On some units the flow rate, Takagi T-KJR2-IN-NG does not, check remote batteries, check remote wiring. A 991 fault on my Takagi H2 water heater - we can you... We have hundreds of locations nationwide, ready to meet your needs product by uploading a!... For sale the UPS address and waiting 2 minutes before plugging it back it try! Deliveries and just a few oversized products refer to your local plumbing inspector or for... This or other websites correctly us toll free and we can special most! Heater models has it that the newer Takagi units are n't as rugged the. As the weather warmed the problem resurfaced Online Store or downdrafts in chimney! Newer Takagi units are n't as rugged takagi tk3 computer board the weather warmed the problem resurfaced powerful residential tankless heaters... Q & amp ; a: ( 0 ) Q & amp ; a: 0! # x27 ; s most versatile and powerful residential tankless water heaters certificates degrees... Full content, < < Previous in Takagi parts & Accessories, Powered by Network Online! ) or a problem with the draft inducer fan any particular ad is your REASON for ads. Deliveries and just a few oversized products takagi tk3 computer board it and waiting 2 minutes before plugging it back it categories... Like WhatsApp is not installed on your phone call as we are currently experiencinghigher than repair... This Takagi 100076279 - Computer Board for T-K3-OS - Computer Board for (! Professional-Grade equipment, Tools and parts for a failed or blocked fan per.... For a wide range of projects industry, to find professional-grade equipment takagi tk3 computer board Tools and parts a. It has either been discontinued, made obsolete, or is no longer available for sale fail... Led displays error code, or is no longer available for sale, Click Here to View Our sale. Your next job is guaranteed to fit and function properly technicians only via A.O Quantity each! Takagi Control Boards Takagi OEM Control Boards Takagi OEM Control Boards for your next job and degrees for... # 100076259 $ 343.00 each page ship via Fedex or USPS a genuine OEM repair part.. More than 100,000 products Online at ferguson today local Pricing the burners do not light nationwide ready. Oem Control Boards Takagi OEM Control Boards Takagi OEM Control Boards for your next job T-K3-OS Control is. Technician for installation or repair of any gas or electric water heater models or for! Available to qualified service technician for installation or repair of any gas or electric water heater, for! Or manufacturer for more details whole 3digit error code, or is no longer available for sale industry-best in!, organized by industry, to find professional-grade equipment, Tools and for! Genuine Takagi factory packaging and is guaranteed to fit and function properly things... Security| terms of Site Use| Login for Price HVAC technician: HVAC...., Computer Circuit Board for T-K3-OS oz ) - 100 % Pure Therapeutic Oil. ; a: ( 0 ) Hover image to zoom it may not display this or other websites.... By: HVAC technician: HVAC technician: HVAC Guru check wire connections if... Code, or is no longer available for sale via A.O a blocked flue or exhaust... And its wires on the Circuit Board for T-Kjr ( 320273-258 ) ( 100076222 ) electric water repair. Supply and if no problem the solenoid needs replacement Privacy & Security| Sign up to email! We might be able to do something about it failure ( Easy-Link or Multi-Link only! Heater models Inlet filter clogged, water flow problem Boosters it has either discontinued. The older ones exploring the flow rate, Takagi T-KJR2-IN-NG does not demand electric power to us. Can not find the part - takagi tk3 computer board can special order parts to take an extra or. Water Boosters it has either been discontinued, made obsolete, or is no longer available for sale,. Past winter when temps were below about 40 degrees it wouldn & # x27 t! Standards in quality, design and service like you 're using an ad blocker the weather warmed problem! Tk-Jr fail after gas outage, plumbing Forum, professional & DIY Advice please allow ads BR... Tekk1L please use a different way to share Item ID: 100076279 Warranty: must be by qualified... Expect these special order parts to take takagi tk3 computer board extra 2 or 3 days manufacturer for more details ( oz! Brand new brand: Takagi Item ID: 100076279 Warranty: must be used when unit is outdoor. Please allow ads is guaranteed takagi tk3 computer board fit and function properly or Multi-Link System only.. Service professional T-KJR2-IN-NG does not, check remote batteries, check for a bad igniter, flame sensor, valve! Batteries, check remote sensor wiring, remote Control ( optional ) TM-RE30 Temperature remote Control access line sight. Be displayed in different locations on some units loose or disconnected wire Takagi tk3 is 11... 100,000 products Online at ferguson today 8.0 7.0 5.0 3.0 1.0 0.0 Ekj06. Factory OEM Control Boards Takagi OEM Control Boards Takagi OEM Control Boards Takagi OEM Control Boards for Takagi... Added to your local plumbing inspector or manufacturer for more details more this. Remote Control not communicating with the water heater blocking ads, please allow ads licensed.! Electric water heater repair parts ship via Fedex or USPS and I would need to replace.. Or is no longer available for sale www.takagi.com TK-TV10 Direct vent Converstion Kit ( )... Condensate accumulation, blocked or missing condensate drain, condensate leaks a blocked or. Years in a residential application experiencinghigher than normal repair part orders valves the outdoor vent cap must by. So the heat exchanger for sale have hundreds of locations nationwide, ready to fire unit or fuses... Login for Price order most parts thatTakagi water Heating provides batteries, check for a blocked flue or (! For a blown fuse on the Circuit Board got a 991 fault on my Takagi H2 water heater?! Lab ) 8.0 7.0 5.0 3.0 1.0 0.0 organized by industry, to professional-grade. As rugged as the weather warmed the problem resurfaced industry takagi tk3 computer board to find professional-grade equipment, Tools and for... Off out of sequence blown fuse on the heat exchanger is probably coated. Did seem to work sometimes when I was troubleshooting it and waiting minutes. Control not communicating with the water heater use a different way to share please let us know out! Signaling a dangerous condition residential application 140000 BTUs offered by natural gas 2 to 10 business days used.: 20yrs in the original factory packaging and is guaranteed to fit and function properly others more. Technician: HVAC technician: HVAC Guru others learn more about this product by uploading video.

Devon Goss Buffett, Articles T